Dwyer CMT200 Carbon Monoxide Transmitter – Field-Replaceable Electrochemical Sensor for Parking Garages
In underground parking garages, commercial basements, and vehicle maintenance facilities, toxic Carbon Monoxide (CO) gas build-up from engine exhaust poses a silent, lethal hazard. To trigger automated exhaust ventilation fans per safety and building codes, the Dwyer CMT200 Carbon Monoxide Transmitter incorporating advanced electrochemical sensing technology is the top specified choice in M&E engineering blueprints.
Dwyer CMT200 Carbon Monoxide Transmitter - Distributed by DLK
1. Standout Advantages of the Dwyer CMT200
The Dwyer CMT200 (Series CMT200 Carbon Monoxide Transmitter) effectively minimizes long-term OPEX for facility managers through innovative design:
-
Field-Replaceable Electrochemical Sensor Module: After a 3 to 5-year operational lifespan, maintenance technicians simply plug in a new pre-calibrated sensor element without dismounting electrical conduit or purchasing a whole new transmitter, cutting maintenance costs by up to 60%.
-
Standard 0 - 200 PPM Measuring Range: Perfectly covers toxic CO hazard thresholds mandated by OSHA and international safety standards with ±2% FS accuracy.
-
Field-Selectable Analog Outputs: An onboard jumper easily selects between 4-20 mA or 2-10 VDC output signals, ensuring 100% compatibility with DDC/BMS controllers or VFD fan drives.
-
UL94V-0 Flame-Retardant Polycarbonate Housing: Features a rugged, flame-retardant enclosure built to withstand mechanical impacts and harsh chemical dust in garage environments.
2. Detailed Technical Specifications
|
Specification |
Details |
|
Model |
CMT200 |
|
Manufacturer |
Dwyer (USA) |
|
Sensing Technology |
Field-replaceable Electrochemical Cell |
|
CO Measurement Range |
0 to 200 ppm |
|
Accuracy |
±2% Full Scale @ 25°C |
|
Response Time |
< 30 seconds (90% step change) |
|
Analog Output Signals |
4-20 mA or 2-10 VDC (Jumper selectable) |
|
Enclosure Material |
UL94V-0 Flame-retardant Polycarbonate |
|
Certifications |
CE, RoHS compliant |
3. Energy-Saving Applications in Basement Ventilation (Demand Controlled Ventilation)
Operating garage exhaust fans continuously 24/7 wastes tremendous electricity. Integrating Dwyer CMT200 CO transmitters achieves intelligent automated control:
-
CO Level < 25 ppm: Exhaust fans operate at low speeds or remain standby to conserve power.
-
CO Level 25 - 50 ppm: BMS signals VFDs to ramp up fan speeds to purge fresh air.
-
CO Level > 100 ppm: Triggers 100% full-capacity ventilation and activates audible alarms for emergency toxic gas evacuation.
⚠️ Field Installation Pro-Tip: CO gas has a molar mass close to air (m=28 g/mol) and diffuses evenly. Install CMT200 transmitters at breathing zone height (1.5m to 1.8m above finished floor level) with a coverage radius of 20 to 25 meters per sensor.
4. Order Genuine Dwyer CMT200 Transmitters at DLK
DLK TRADING SERVICE COMPANY LIMITED directly distributes Dwyer CMT200 CO sensors alongside genuine replacement sensor elements. DLK guarantees:
-
✅ Authentic USA imported devices with full CO and CQ documentation.
-
✅ Video tutorials covering configuration and field calibration procedures.
-
✅ Ready stock of spare electrochemical sensor cells for continuous plant operation.
📞 Contact DLK for Technical Consultation & Quotations