RT-3000-P APC by Apollo Duct Smoke Detector – Early Fire Detection for HVAC Systems

Posted on: 22/07/2026

Ductwork is a primary pathway through which smoke can rapidly spread throughout a building in the event of a fire. Therefore, installing dedicated smoke detectors directly inside ductwork is a mandatory requirement under current fire safety regulations. The RT-3000-P model from APC by Apollo is a Duct Smoke Detector preferred by many M&E contractors due to its high reliability and flexible integration with central fire alarm systems.

Introduction to RT-3000-P Duct Smoke Detector

The RT-3000-P delivers an early smoke detection solution featuring dual detector technologies: engineers can select either photoelectric or ionization heads depending on the specific project requirements. The unit automatically detects the operating voltage (24 VAC/VDC or 115/230 VAC) and features built-in DPDT relays, allowing fan shutdown control and direct connection to the central fire alarm panel.

Duct Smoke Detector APC RT-3000-P

Technical Specifications

Specifications

Details

Brand

APC by Apollo (USA)

Power Supply

24 VAC/VDC, 115 VAC, or 230 VAC (50/60 Hz)

Relay Contacts

DPDT (10A @ 115 VAC)

Air Velocity

100 to 4,000 ft/min (0.5 – 20.3 m/s)

Operating Temperature

32°F to 140°F (0°C to 60°C)

Operating Humidity

0% to 85% RH (non-condensing)

Detector Technology

Photoelectric or Ionization (Optional)

Enclosure Design

Clear cover for visual LED inspection without opening the unit

Certifications

UL, CSFM, MEA, FM

Warranty

12 months (Optional upgrade to 36 months)

Installation & Operating Guide

  1. Identify the installation location on the ductwork in accordance with local fire safety codes—typically located on main return air or supply air ducts, before or after AHU filters.

  2. Verify air velocity at the installation spot falls within the permitted range (100–4,000 ft/min). If velocity is too low or too high, adjust the location or re-engineer the sampling tube setup.

  3. Mount the housing unit to the outer wall of the duct and insert the sampling tube across the duct cross-section according to the actual duct size.

  4. Connect the power supply according to the auto-sensing voltage (24 VAC/VDC or 115/230 VAC), and wire the DPDT relay outputs to the fan control circuit and central fire alarm system.

  5. Test the device via the test port and magnet test procedure as specified by the manufacturer, without needing to dismantle the unit.

  6. Observe the LED status indicator through the clear cover to confirm normal operating or alarm state.

  7. Schedule periodic maintenance and testing as mandated by fire safety regulations (typically every 6 months) to ensure continuous operational readiness.

Note: Wiring to central fire alarm panels must comply with applicable fire regulations and should be carried out by qualified contractors and approved by local fire safety authorities.

Practical Applications

  • Installed on main duct lines of commercial and industrial HVAC systems.

  • Integrated with central fire alarm panels to automatically shut down supply/return fans upon smoke detection.

  • Ideal for shopping malls, hospitals, factories, and commercial office buildings.

  • Meets fire inspection and acceptance requirements for building ventilation systems.

Why Buy RT-3000-P from DLK?

  • 100% Authentic Products: Direct distribution of APC by Apollo with full UL/FM certifications and CO/CQ documents.

  • Technical Support: Professional guidance on choosing detector technologies and sampling locations per fire protection designs.

  • Complete Documentation: Fully detailed technical catalogs provided to support project submittals and approvals.