RT-3000-P APC by Apollo Duct Smoke Detector – Early Fire Detection for HVAC Systems
Posted on: 22/07/2026
Ductwork is a primary pathway through which smoke can rapidly spread throughout a building in the event of a fire. Therefore, installing dedicated smoke detectors directly inside ductwork is a mandatory requirement under current fire safety regulations. The RT-3000-P model from APC by Apollo is a Duct Smoke Detector preferred by many M&E contractors due to its high reliability and flexible integration with central fire alarm systems.
Introduction to RT-3000-P Duct Smoke Detector
The RT-3000-P delivers an early smoke detection solution featuring dual detector technologies: engineers can select either photoelectric or ionization heads depending on the specific project requirements. The unit automatically detects the operating voltage (24 VAC/VDC or 115/230 VAC) and features built-in DPDT relays, allowing fan shutdown control and direct connection to the central fire alarm panel.

Technical Specifications
|
Specifications
|
Details
|
|
Brand
|
APC by Apollo (USA)
|
|
Power Supply
|
24 VAC/VDC, 115 VAC, or 230 VAC (50/60 Hz)
|
|
Relay Contacts
|
DPDT (10A @ 115 VAC)
|
|
Air Velocity
|
100 to 4,000 ft/min (0.5 – 20.3 m/s)
|
|
Operating Temperature
|
32°F to 140°F (0°C to 60°C)
|
|
Operating Humidity
|
0% to 85% RH (non-condensing)
|
|
Detector Technology
|
Photoelectric or Ionization (Optional)
|
|
Enclosure Design
|
Clear cover for visual LED inspection without opening the unit
|
|
Certifications
|
UL, CSFM, MEA, FM
|
|
Warranty
|
12 months (Optional upgrade to 36 months)
|
Installation & Operating Guide
-
Identify the installation location on the ductwork in accordance with local fire safety codes—typically located on main return air or supply air ducts, before or after AHU filters.
-
Verify air velocity at the installation spot falls within the permitted range (100–4,000 ft/min). If velocity is too low or too high, adjust the location or re-engineer the sampling tube setup.
-
Mount the housing unit to the outer wall of the duct and insert the sampling tube across the duct cross-section according to the actual duct size.
-
Connect the power supply according to the auto-sensing voltage (24 VAC/VDC or 115/230 VAC), and wire the DPDT relay outputs to the fan control circuit and central fire alarm system.
-
Test the device via the test port and magnet test procedure as specified by the manufacturer, without needing to dismantle the unit.
-
Observe the LED status indicator through the clear cover to confirm normal operating or alarm state.
-
Schedule periodic maintenance and testing as mandated by fire safety regulations (typically every 6 months) to ensure continuous operational readiness.
Note: Wiring to central fire alarm panels must comply with applicable fire regulations and should be carried out by qualified contractors and approved by local fire safety authorities.
Practical Applications
-
Installed on main duct lines of commercial and industrial HVAC systems.
-
Integrated with central fire alarm panels to automatically shut down supply/return fans upon smoke detection.
-
Ideal for shopping malls, hospitals, factories, and commercial office buildings.
-
Meets fire inspection and acceptance requirements for building ventilation systems.
Why Buy RT-3000-P from DLK?
-
100% Authentic Products: Direct distribution of APC by Apollo with full UL/FM certifications and CO/CQ documents.
-
Technical Support: Professional guidance on choosing detector technologies and sampling locations per fire protection designs.
-
Complete Documentation: Fully detailed technical catalogs provided to support project submittals and approvals.
-
Transparent Warranty: Fast and reliable technical customer support.
Contact DLK for Consultation & Quotes