Guide to Selecting the Right Dwyer Sensors for Efficient HVAC and AHU Systems

Guide to Selecting the Right Dwyer Sensors for Efficient HVAC and AHU Systems

Guide to Selecting the Right Dwyer Sensors for Efficient HVAC and AHU Systems

Posted on: 08/07/2025

In HVAC (Heating, Ventilation, and Air Conditioning) systems and Air Handling Units (AHUs), sensors play a crucial role in monitoring and controlling parameters such as differential pressure, airflow, temperature, and humidity.

Selecting the correct Dwyer sensor not only enhances system performance but also reduces operating and maintenance costs.

With extensive experience distributing official Dwyer sensors in Vietnam, DLK provides this practical guide to help you choose the right sensor for each point in your HVAC or AHU system.

1. Essential Sensor Types in HVAC & AHU Systems

Typical measurement needs in HVAC and AHU include:

  • Differential Pressure – e.g., across air filters, fans, ductwork
  • Airflow – to monitor ventilation rate and fan performance
  • Temperature & Humidity – for environmental control in rooms or ducts
  • Duct and Chilled Water Pressure – for air or water line monitoring

Each application requires a specific sensor type.

 Essential Sensor Types in HVAC & AHU Systems

2. Sensor Selection Guide by Installation Location

A. Measuring Differential Pressure in Ducts & Filters

Recommended Models:

  • Dwyer SERIES 2000 (mechanical, Magnehelic® gauge)
  • Dwyer MSX / Magnehelic® Series (durable and accurate)
  • Dwyer SERIES 629 (with analog signal output)

Installation points:

Before and after HEPA filters, boost fans, or silencers

B. Measuring Room Static or Positive Pressure

Recommended Models:

  • Dwyer SERIES 616KD (high accuracy, 4–20mA output)
  • Dwyer TDFS / T6861H2WB (LCD display, user-friendly)

Applications:

Cleanrooms, operating rooms, positive/negative pressure control

C. Measuring Airflow in Ducts

Recommended Models:

  • Dwyer SERIES 160 / 166T (pitot tubes with pressure sensors)
  • Dwyer SERIES STA / DPT-FLOW (integrated pressure and flow)

Installation:

In main ducts or post-fan sections

D. Measuring Temperature and Humidity

Recommended Models:

  • Dwyer SERIES RH-R (combined temperature/humidity sensor)
  • Dwyer RHP Series (options with Modbus or BACnet output)

Application:

Room or duct environmental monitoring

E. Measuring Chilled Water Line Pressure

Recommended Models:

  • Dwyer SERIES 629C or 682 (high-pressure liquid sensors)

Installation location:

On supply or return lines of chilled water systems

3. Key Considerations When Selecting a Dwyer Sensor

To select the most suitable model, consider:

Criteria

Recommendations

Parameters to Measure

Pressure, temperature, humidity, flow rate...

Size Compatibility

Do not choose excessively large sizes as it may cause significant errors

Output Signal

0–10V, 4–20mA, Modbus RTU, BACnet MS/TP...

Material Suitability

Choose anti-corrosion and dustproof materials suitable for HVAC/industrial conditions

Brand and Certification

Consider brands like Dwyer with certifications such as CE, RoHS, ISO

Integration Capability

Compatible with BMS, PLC, SCADA systems or centralized control devices

4. DLK – Official Dwyer Sensor Distributor for HVAC & AHU in Vietnam

DLK (Long Khanh Electrical Engineering Trading Co., Ltd.) is the official distributor of Dwyer Instruments in Vietnam, specializing in sensor solutions for HVAC, AHU, cleanroom, and industrial applications.

With DLK, you get:

  • Expert advice on selecting the right sensor for each system location
  • Genuine products with full CO, CQ, and warranty
  • Competitive pricing and on-site technical support for installation & calibration
  • In-stock inventory for fast nationwide delivery

Contact DLK today for personalized consultation and a fast quote!