Specification |
Description |
Service |
Compatible clean or dirty non-coating, conductive liquids |
Range |
0 to 20 ft/s (0 to 6 m/s). For max flowrates >10 ft/s (3 m/s) order option -CC |
Wetted Materials |
Body shaft/fitting: 316 SS; Electrodes: 316 SS; Electrode cap: Polymer/polystyrene; O-ring: Silicone; Thermowells: 304 SS |
BTU Accuracy |
High Accuracy Units: Class 2 (2 to 20 ft/s); Standard Accuracy Units: Class 3 (6.5 to 20 ft/s) |
Flow Sensor Accuracy |
High Accuracy Units: ±0.5% of reading, ±1% (2 to 20 ft/s); Standard Accuracy Units: ±1% FS |
Temperature Accuracy |
Class B ±(0.30 + 0.005*t)°C per EN60751 |
Differential Temperature Accuracy |
Et = ±[0.5 +3*(Delta)(Theta)min/(Delta)(Theta)] % |
Calculator Accuracy |
Ec = ±[0.5 +(Delta)(Theta)min/(Delta)(Theta)] % |
Temperature Compensation |
140 to 220°F, < 2% error over ±30°F; 40 to 70°F, < 2% error over ±10°F |
Temperature Limits |
Ambient: -20 to 160°F; Process: 15 to 250°F; Storage: -40 to 185°F |
Process Connection |
Flowmeter: 1" NPT or BSPT; Thermowell: (2) 1/2" NPT or BSPT |
Pressure Limit |
400 psi (27.6 bar) @ 100°F |
Pressure Drop |
< 0.1 psi at 12 ft/s in 4" pipe |
Outputs |
Analog, Pulse/Frequency, Alarm |
Power Requirements |
12-42 VDC, 12-36 VAC |
Electrical Connection |
Removable terminal blocks, multiple conduit options |
Display |
2 x 2" graphic LCD with backlight |
Conductivity |
>20 microsiemens |
Enclosure Material |
Powder coated die cast aluminum |
Enclosure Ratings |
NEMA 6P (IP68) or NEMA 4X (IP66) |
Agency Approvals |
BTL |
Communication Options |
BACnet MS/TP or Modbus RTU |
Applicable Pipe Material |
Carbon steel, SS, copper, UPVC, PVDF, etc. |
Applicable Pipe Size |
4 to 36" (100 to 900 mm) |
Diameter Length Requirements |
>10 upstream, >5 downstream |
Relative Humidity |
10 to 90% non-condensing |
Output Impedance |
4 to 20 mA: 536 Ω; 10V: 1.27k Ω |