Complete NCT oil leak detection system: selective NA03AA oil sensor cable (no water alarms), NB01AA 2-channel controller with Form C relays, RS-485 Modbus and IoT LoRa, NC01AA connectors and protective cases. For diesel generator rooms, day tanks, fuel pump stations and hydraulic rooms.

Product information

The NCT Oil Leak Detection Kit gives early warning of diesel, gasoline, turbine oil and organic solvent leaks; the NA03AA cable reacts only to oil, so water causes no false alarms – for generator rooms, fuel tanks and pump stations.

The kit includes NA03AA cable (per metre), the NB01AA controller (2 zones, Form C relays, RS-485 Modbus) and NC01AA connectors; connects to BMS/SCADA or the ND01AA alarm panel. Genuine products supplied by DLK Trading Service Company Limited – NCT's authorized strategic partner in Vietnam.

Tags:
  • 🚚 Direct Importer by  DLK TRADING SERVICE COMPANY LIMITED .
  • ✅ Quality :  100% Brand New , genuine products with complete import documentation.
  • 🛠️ Warranty :  12 Months (optional 36 Months ).
  • 📞 Phone  :  0937972339

What is included in the solution?

Signals are processed by the 2-channel NB01AA controller with a real-time display, site-adjustable alarm thresholds, 2 Form C relays for interlocks and beacons, and an RS-485 Modbus port to BMS/SCADA/DCS; optional IoT LoRa mobile alerts.

Component Code Function Quantity rule Type
Oil leak sensor cable NA03AA Selective response to oil & organic solvents Per metre – per zone length Required
2-channel chemical sensor controller NB01AA Display, alarm, Form C relays, RS-485 Modbus, IoT LoRa 1 per 2 zones Required
Chemical sensor connector NC01AA Connects the film to the controller 2 per zone (both ends) Required
24 VDC power supply SMPS 24VDC Powers the controllers, DIN-rail in panel ≥ 24 VDC / 1 A (per NCT); size up for multiple controllers Required
Master controller NB02AA Central management of up to 30 NB01AA via RS-485 When many NB01AA units are used Optional
Corner / flexible link NC02AA / NC06A Turns and obstacle crossings Per route Optional
SUS / PVC sensor case NF01A-C / NF02A-C Outdoor, tank-farm and impact protection Per protected section Optional
Connector case / cover NF04A / NF05A Connector protection; walkway cover As required Optional
Compact 24 VDC UPS NF07A Keeps leak monitoring alive during outages 1 per panel Optional
Control & alarm panel ND01AA Houses controllers, beacon/siren, WCDMA/RS-485/RF comms Per area / zone count Optional

Required items form the minimum working configuration; Optional items are selected to suit site conditions.

How it works

  • The nano-carbon layer in NA03AA changes resistance on contact with oil/solvent; NB01AA compares it with the initial resistance (in %) and alarms when the lower/upper threshold is crossed.
  • Periodic auto-calibration (P-12…P-14) compensates drift from temperature and humidity – fewer nuisance alarms.
  • On alarm, ALARM1/ALARM2 lights per channel, the relay changes state and data updates over RS-485. After clean-up, replace the contaminated film and reset (P-03 = 1).

Typical applications

  • Diesel generator rooms, day tanks, fuel supply piping
  • Fuel depots, pump/filling stations, tank bunds
  • Hydraulic rooms, turbine lube-oil systems, compressors
  • Technical basements and car parks with oil piping
  • Solvent stores (ethanol, MEK, toluene…) in paint, printing and electronics plants

Benefits for contractors & owners

  • Oil-selective – ignores water: works outdoors and in wash-down areas
  • Also detects common organic solvents (ethanol, MEK, toluene…)
  • Controller with display, site-tuned thresholds and auto-calibration
  • Form C relays + RS-485 Modbus + IoT LoRa – flexible BMS/SCADA/DCS integration
  • Flexible 370 µm film fits flanges, tank bottoms and drip trays
  • S-Mark, CE, KC certified

Technical specifications

NA03AA oil leak sensor cable

Parameter Value
Part number NA03AA
Type Film-type oil leak detection sensor
Detectable substances Petroleum-based oils: gasoline, diesel, kerosene, turbine oil, etc.; organic solvents: ethanol, 2-ethoxyethanol, methyl ethyl ketone, toluene, etc. (others: contact us)
Dimensions Width 36 mm / Thickness 370 µm
Operating temperature -30 to 100 °C
Material PET
Features Reacts directly with oil for fast, accurate detection; selective nano-carbon material – does not alarm on water
Sales unit Per metre
Precaution Not standalone – use with NB01AA controller and NC01AA connectors; replace the sensor after oil contact

NB01AA chemical leak sensor controller

Parameter Value
Part number NB01AA
Channels Up to 2 sensors (CH1, CH2)
Dimensions 96 (W) × 66 (H) × 29 (D) mm
Power supply 24 VDC, 200 mA
Communication RS-485 Modbus, 9,600 bps (ID 1–99); IoT LoRa – monitoring and control via mobile app
Relay output 1 Form C × 2 (one relay per channel), 1 A 24 VDC / 0.5 A 125 VAC
Sensor input range 1 kΩ to 5,000 kΩ
Display / setup 4-digit FND display, STATUS / POWER / ALARM1 / ALARM2 LEDs, 4 setup keys; alarm thresholds & auto-calibration as % of initial resistance (default 80% / 130%)
Data Real-time value on site, sensor response data logging
Operating temperature -30 to 100 °C
Housing material PP
Certifications S-Mark, CE, KC

NB02AA master controller

Parameter Value
Part number NB02AA
Function Centrally manages up to 30 NB01AA controllers in parallel on RS-485
Dimensions 108 (W) × 112 (H) × 35 (D) mm
Power supply 24 VDC, 200 mA
Communication RS-485 Modbus, 9,600 bps
Relay output 1 Form C, 1 A 24 VDC / 0.5 A 125 VAC
Operating temperature -30 to 100 °C
Housing material Aluminium (AL)

Sensor connectors

Code Type Dimensions Notes
NC01AA Chemical sensor connector (NA01AA/NA02AA/NA03AA) 55.5 × 18 × 12.6 mm Single type (no START/END); each connector cable is wired to NB01AA
NC02AA Link (corner) connector 75 × 75 × 12.6 mm For corners/bends; compatible with leak and chemical sensors
NC06A Flexible link connector 55.5 × 18 × 12.6 mm × 2 Adjustable intermediate cable – crosses columns, beams, gaps; compatible with leak and chemical sensors

Material PVC, operating temperature -30 to 100 °C.

Protective accessories & backup power (optional)

Code Name Material Dimensions / data Purpose
NF01A / NF01B / NF01C Sensor protective case (SUS) SUS (inox) 115 × (200–500 / 501–1,000 / 1,001–2,000) × 50 mm Film installed inside; liquid entering through the bottom is detected – mechanical, dirt and outdoor protection
NF02A / NF02B / NF02C Sensor protective case (PVC) PVC 115 × (200–500 / 501–1,000 / 1,001–2,000) × 50 mm For areas where metal cannot be used – especially highly corrosive chemical areas
NF04A Connector protective case SUS 70 × 80 × 50 mm Protects connectors from environmental factors and impact
NF05A Sensor protective cover SUS 40 × 15 × 2,400 mm, 1.2 mm thick Cover over the film, fixed with saddles; label on top – for walkways and trolley areas
NF07A UPS – compact 24 VDC model — 84 × 72 × 42 mm; 14.4 V × 3,000 mAh; I/O 24 V (±10%); 400 g Panel-mounted 24 VDC backup for controllers (KC, CE)
NF06A UPS – standard model — 101 × 279 × 142 mm; 12 V / 7 Ah; I/O 220 VAC (±10%, 50/60 Hz); 4.2 kg Keeps the alarm system running during outages (KC, CE)

Wiring & system integration

BMS / SCADA / DCS integration

Method NB01AA output To system Notes
Relay contacts 2 × 1 Form C relays (NO/NC/COM), one per channel; 1 A 24 VDC / 0.5 A 125 VAC DDC/PLC DI, beacon/siren, pump trip / valve interlock Dry contacts – direct wiring
RS-485 Modbus RS-485 Modbus, 9,600 bps, ID 1–99 (parameter P-01) BMS/SCADA/DCS via Modbus gateway; read status and resistance/% values (U-01, U-05) Multi-drop bus; up to 30 units managed by NB02AA master
IoT LoRa LoRa network Mobile app – remote monitoring & alerts Ideal for unmanned warehouses and remote areas
Quick setup: P-01 = Modbus address; P-02 = number of sensors (1 or 2); P-10/P-11 = lower/upper alarm limits (% of initial resistance, default 80%/130%); P-12/P-13/P-14 = auto-calibration; recommended display U-05. Detailed Modbus register map: supplied by DLK per project.

Installation & operation notes

  • Place the cable at the lowest point oil reaches first: bund floor, drip trays under pumps/valves, along pipe trenches.
  • Insert the film into NC01AA between electrode and rubber seal, with the electrode between the cover film and sensing film; tighten the cover.
  • Wire to NB01AA sensor terminals with correct polarity (+/–), apply 24 VDC; set P-01 (ID), P-02 (sensor count), check U-05 = 100%.
  • Outdoors or in traffic areas use SUS case NF01 or cover NF05A; house connectors in NF04A.

Quantity take-off example

Example: generator room with 2 zones (around day tank 8 m, fuel trench 12 m)

Item Quantity
NA03AA 20 m
NB01AA 1 unit
NC01AA 4 pcs
SMPS 24 VDC ≥ 1 A 1 unit
BMS signals 2 relay contacts + RS-485 Modbus

Frequently asked questions (FAQ)

Does NA03AA alarm on water?

No. NA03AA uses a selective material that reacts only to oil and organic solvents, so it suits outdoor and wash-down areas.

Which oils can it detect?

Gasoline, diesel, kerosene, turbine oil and organic solvents such as ethanol, 2-ethoxyethanol, MEK and toluene. For other oils, contact DLK for testing.

How does NB01AA connect to the BMS?

Two Form C relays (dry contacts) and an RS-485 Modbus port at 9,600 bps. Units can share one bus; NB02AA manages up to 30 units centrally.

Can the cable be reused after a leak?

The film section that contacted oil must be replaced; connectors and controller stay. Reset with P-03 = 1 after replacement.

Is backup power needed?

A 24 VDC NF07A or NF06A UPS is recommended so alarms keep working during outages.

DLK Trading Service Company Limited is NCT's (Nano Composite Technology, Korea) authorized strategic partner in Vietnam. DLK supplies 100% new genuine products with full import documents, and supports contractors and factories with system sizing and BOQ take-off from drawings, wiring, commissioning and signal integration into BMS / SCADA / DCS.
Need a quotation from drawings / BOQ? Send DLK your layout and the list of zones to monitor – DLK engineers will propose the configuration, take off quantities and provide a BMS wiring diagram. Hotline: +84 93 279 2697 – Sales: +84 70 357 0101.

Data sources: NCT catalog, NCT Leak Sensor Manual, NCT All Conductive Liquid Sensor Manual, nctech.co.kr. Specifications may change with product revisions – please confirm with DLK before ordering.

Mã SP:

Quy cách:

Tình trạng:

Price:

Số lượng

0703570101